Hot spot detection
We distribute liquid crystals for hot spot detection in semiconductor devices which we took over from Merck Darmstadt in 2008.
Liquid crystals for hot spot detection in semiconductor devices
(nematic single compounds)
Acronym Melting point Clearing point
°C °C
K18 15 29
K 15 23 35
ME6N 46 48
N4 20 74
I52 26 104
HP2N 112 217
Quantities: 5g, 10g, 25g, bigger quantities and prices on request
Lit:
E.M. Fleuren, A very sensitive, simple analysis technique using nematic liquid crystals,
1983, Proceeding of the 21st Annual International Reliability Physics Symp., 148-149.
R. Weyl et al., Thermographie an integrierten Schaltungen, NTG-Fachberichte 86, 116-120
(1985)
...back to Production & Distribution